Restore accurate temperature sensing and consistent performance with this thermocouple. Working with the temperature controller, it monitors heater temperature to prevent overheating and to support clean, low-odour incineration. The thermocouple sits to the right of, and midway between, the heater terminals; the tip must touch the lower heater coil for correct readings. 

 

Key Features

Type K sensing, provides the controller with precise temperature feedback to protect the heater and improve burn consistency. 

Correct placement guidance, tip contacts the lower heater coil for reliable operation. 

OEM part listing with SKU THE009, sized for easy routing inside the chamber. 

 

Compatibility

Used across Incinolet configurations, select by part name and location rather than voltage or serial number. 

 

What’s Included

1 × Thermocouple; SKU THE009. 

 

Installation & Care (Quick Tips)

Unplug the unit, remove ashpan, access panel and top to reach the heater area. 

Route the new thermocouple as shown in the manual, position the tip so it touches the lower heater coil, then secure wiring. 

After reassembly, run a test cycle and confirm normal heater control.

 

Specs

Type: K thermocouple, chamber-mounted. 

SKU: THE009. 

Approx. weight: 0.125 lb; dimensions: 8 × 1 × 1 in. 

 

FAQs

What does the thermocouple do?

It measures heater temperature and signals the controller to regulate or stop heat, helping prevent overheating. 


Where exactly is it located?

To the right of, and midway between, the heater terminals; the tip rests against the lower heater coil. 


Is this part voltage or serial specific?

No, choose by part name and location; it is used across configurations. 


Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.